VDO Gauges do not come with wiring instructions, so......
The two large poles are used to hold the 'U' clamp that keeps the gauge in position and do not have any wiring attached to them.
The small pole that has a 'G' next to it is there so that you can attach the wire that is being run to the sender. Remember that the sender must also have a wire running back to negative on your battery. This could be the earth strap on your engine if it runs back to the battery.
The small pole that has a '+' next to it needs a (12 volt or 24 volt depending on gauge type) live feed from a switch and fuse. The gauge will draw 1.25 amp max.
The small pole that has a '-' next to it returns to your battery.
The red wire provides power to the gauge internal lamp. This requires 12V feed from a switch and fuse and will consume 0.05 amps when running. 
Please note there is no wiring for the internal lamp negative. there is internal wiring that takes that to the correct pole.
Please note. The Battery gauge - Volt gauge (12 or 24 volt) will only have two poles, so no 'G' pole.
0 Comments



Leave a Reply.

    Author

    The purpose of this blog is to help. Please ask your questions and give your feedback and observations.

    Archives

    October 2019
    May 2019
    February 2019
    October 2018
    September 2018
    June 2018
    May 2018
    March 2018
    February 2018

    Categories

    All
    Fuel Tank
    Fuse & Relay
    Gauges
    Starting Pre Heat & Prime
    Starting Pre-Heat & Prime
    Wiring

    RSS Feed

    View my profile on LinkedIn

Dragon Marine Systems

Custom marine control panels - Designed in the UK.


Address:

Dragon Marine Systems
Unit 3
Thornbury
Bristol
BS35 2AR

Telephone Number:

​​+(44) 07513 844841

Email Address:

[email protected]
  • Home
  • Featured Collection
    • Wiring Looms
    • Sensors
    • Switches
    • Alternators
    • Stock Panels
  • Support
    • About Us
    • Contact Us
    • Tips & Questions >
      • Support Video
      • Helm & Flybridge
    • Identifying Components >
      • Alternator and Sensors
      • ECMS Gauges
      • VDO Gauges
    • Warranty and fitting >
      • D.m.s Safety
      • Wiring Diagrams
      • Fitting And Cautions
    • FAQ's >
      • Volvo Penta Panel Replacement